1. Model: AK-200FC/C4
2. Sensor: electrochemical carbon monoxide sensor
3. Detecting range: 0~999PPM*
sensitivity: 5PPM
4. Error: ±10%+15PPM
(The detecting precision is effected by detector itself and the temperature and humidity of the installation environment.
the best installation environment: 20°C±5°C; relative humidity 50%±3%; air pressure ±10%.)
5. Numerical readings and notes: 3-digit LCD display of levels
6. Normal reading: 0
7. Alarm readings: 30~999PPM
8. Battery capacity display: full, OK, low, dead
9. Sensor performance display: malfunction
10. Alarm mode: sound: beep, hummer
11. Light: red LED flashing
12. Installation: wall & table
Carbon Monoxide Detector